11 Nau'in Cutar Cutar Numfashi

Takaitaccen Bayani:

Ana amfani da wannan kit ɗin don gano in vitro qualitative ganewar asali na na kowa asibiti na numfashi pathogens a cikin mutum sputum, ciki har da Haemophilus mura (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumonialt, maltno Bortephia (KhomonadeS), ma'aunin zafi da sanyio. pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Kafa). Za a iya amfani da sakamakon a matsayin taimako a cikin ganewar asali na asibiti ko marasa lafiya marasa lafiya da ake zargi da kamuwa da cututtukan cututtuka na numfashi.Ana amfani da wannan kit ɗin don gano in vitro qualitative ganewar asali na na kowa asibiti na numfashi pathogens a cikin mutum sputum, ciki har da Haemophilus mura (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumonialt, maltno Bortephia (KhomonadeS), ma'aunin zafi da sanyio. pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Kafa). Za a iya amfani da sakamakon a matsayin taimako a cikin ganewar asali na asibiti ko marasa lafiya marasa lafiya da ake zargi da kamuwa da cututtukan cututtuka na numfashi.


Cikakken Bayani

Tags samfurin

Sunan samfur

HWTS-RT162A 11 Nau'ikan Na'urar Gano Kwayoyin Ganewa Na Nukiliya(Pluorescence PCR)

Tashoshi

靶标 Tashoshi
核酸反应液A 核酸反应液B 核酸反应液C 核酸反应液D
HI Smet MP Kafa FAM
SP PA Bp / CY5
KPN ABA Bpp Cpn ROX
内参 内参 内参 内参 VIC/HEX

Epidemiology

Cututtukan da suka shafi hanyoyin numfashi wani nau’in cututtuka ne masu muhimmanci da ke haifar da babbar barazana ga lafiyar dan’adam, kuma bincike ya nuna cewa galibin cututtukan da ke kamuwa da cutar ta numfashi na faruwa ne ta hanyar kwayoyin cuta da kwayoyin cuta ko kwayar cuta da suka hada da cutar da mai gida, wanda ke haifar da tsananin cutar har ma da mutuwa, don haka fayyace kwayar cutar ta ba da damar samun magani da aka yi niyya da kuma inganta rayuwar mara lafiya.[1,2].

Ma'aunin Fasaha

Adana

≤-18℃

Rayuwar rayuwa watanni 12
Nau'in Samfura Sputum
Ct HI, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Kafa: Ct≤38
CV <5.0%
LoD Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia da Legionella.pneumophila: 1000 CFU/ml;

Bordetella pertussis da Bacillus parapertussis: 500 CFU/ml;

Mycoplasma pneumoniae da Chlamydia pneumoniae: 200 kwafi/ml.

Musamman Sakamakon gwajin giciye-reactivity ya nuna cewa babu wani ra'ayi tsakanin wannan kit da Cytomegalovirus, Herpes simplex virus type 1, Varicella-zoster virus, Epstein-Barr virus, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinshala, Molisinsha, Molisinsha, Molisinshala Cattenumophila, Molisella. Kwayoyin cutar tarin fuka, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas Burholders Burholders, Corynebacteria. Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Klebsiella pneumoniae, Klebsiella pneumoniae.
Abubuwan da ake Aiwatar da su Abubuwan da aka Aiwatar da Biosystems 7500 Tsarin PCR na Gaskiya

Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time

QuantStudio®5 Tsarin PCR na Gaskiya

SLAN-96P Tsarin PCR na Gaskiya

LightCycler®480 Real-Time PCR tsarin

LineGene 9600 Plus Tsarukan Gane PCR na Gaskiya

MA-6000 Mai ƙididdige yawan zafin jiki na ainihi

BioRad CFX96 Tsarin PCR na Gaskiya

BioRad CFX Opus 96 Tsarin PCR na Gaskiya

Gudun Aiki

Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3019) (wanda za'a iya amfani dashi tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ƙara 200µL nailimin lissafiSaline zuwa hazo da aka sarrafa, kuma ya kamata a aiwatar da matakan da suka biyo baya daidai da umarnin. Adadin da aka ba da shawarar shine 100µL.


  • Na baya:
  • Na gaba:

  • Ku rubuta sakonku anan ku aiko mana