12 Nau'in Cutar Cutar Numfashi
Sunan samfur
HWTS-RT071A 12 Nau'in Na'urar Gano Kwayoyin Ganewa Na Numfashi Pathogen Nucleic Acid (Fluorescence PCR)
Tashoshi
Tashoshi | hu12Reaction Buffer A | hu12Ra'ayin Buffer B | hu12Ra'ayin Buffer C | hu12Reaction Buffer D |
FAM | SARS-CoV-2 | HADV | Kwayar cutar ta HPIV | HRV |
VIC/HEX | Ikon Cikin Gida | Ikon Cikin Gida | Kwayar cutar ta HPIV | Ikon Cikin Gida |
CY5 | IFV A | MP | Kwayar cutar ta HPIV | / |
ROX | Farashin B | RSV | Kwayar cutar ta HPIV | HMPV |
Ma'aunin Fasaha
Adana | ≤-18℃ |
Rayuwar rayuwa | watanni 12 |
Nau'in Samfura | Oropharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | SARS-CoV-2: Kwafi 300/mlmura B: 500 Kwafi/mlmura A virus: 500 Copy/ml Adenovirus: 500 Kwafi/ml mycoplasma pneumoniae: 500 kwafi/ml Kwayoyin syncytial na numfashi: 500 Copy/ml, kwayar cutar parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ):500 Copy/ml Rhinovirus: 500 Kwafi/ml mutum metapneumovirus: 500 kwafi/ml |
Musamman | Binciken giciye-reactivity ya nuna cewa babu wani haɗin kai tsakanin wannan kit da enterovirus A, B, C, D, cutar epstein-barr, cutar kyanda, kwayar cutar kyanda, cytomegalovirus mutum, rotavirus, norovirus, cutar mumps, varicella-herpes zoster virus, bordetella pertussis, streptococcus, da tarin fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka, fuka pyogenes. Candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans da kuma ɗan adam genomic nucleic acid. |
Abubuwan da ake Aiwatar da su | Abubuwan da aka Aiwatar da Biosystems 7500 Tsarin PCR na GaskiyaAbubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-TimeQuantStudio®5 Tsarin PCR na Gaskiya SLAN-96P Tsarin PCR na Gaskiya (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Tsarin PCR na ainihi, Tsarin Gano PCR na LineGene 9600 Plus (FQD-96A, fasahar Hangzhou Bioer) MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Tsarin PCR na Gaskiya BioRad CFX Opus 96 Tsarin PCR na Gaskiya |
Gudun Aiki
Zabin 1.
Nasihar hakar reagent: Macro & Micro-Test Samfurin Sakin Reagent (HWTS-3005-8) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ya kamata a aiwatar da hakar a cikin tsananin daidai da umarnin.
Zabin 2.
Nasihar hakar reagent: Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006H300C) Micro-Test Med-Tech Co., Ltd., hakar ya kamata a gudanar bisa ga umarnin sosai. Adadin da aka ba da shawarar shine 80μL.
Zabin 3.
Shawarar hakar reagent: Nucleic Acid hakar ko Tsarkake Kit (YDP315) ta Tiangen Biotech(Beijing) Co., Ltd., da hakar ya kamata a gudanar bisa ga umarnin sosai. Adadin da aka ba da shawarar shine 100μL.