12 Nau'in Cutar Cutar Numfashi
Sunan samfur
HWTS-RT071A 12 Nau'in Na'urar Gano Kwayoyin Ganewa Na Numfashi Pathogen Nucleic Acid (Fluorescence PCR)
Tashoshi
Tashoshi | hu12Reaction Buffer A | hu12Ra'ayin Buffer B | hu12Ra'ayin Buffer C | hu12Reaction Buffer D |
FAM | SARS-CoV-2 | HADV | Kwayar cutar ta HPIV | HRV |
VIC/HEX | Ikon Cikin Gida | Ikon Cikin Gida | Kwayar cutar ta HPIV | Ikon Cikin Gida |
CY5 | IFV A | MP | Kwayar cutar ta HPIV | / |
ROX | Farashin B | RSV | Kwayar cutar ta HPIV | HMPV |
Ma'aunin Fasaha
Adana | ≤-18℃ |
Rayuwar rayuwa | watanni 12 |
Nau'in Samfura | Oropharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | SARS-CoV-2: Kwafi 300/mlmura B: 500 Kwafi/mlmura A virus: 500 Copy/ml Adenovirus: 500 Kwafi/ml mycoplasma pneumoniae: 500 kwafi/ml Kwayoyin syncytial na numfashi: 500 Copy/ml, parainfluenza virus (Ⅰ, Ⅱ, Ⅲ, Ⅳ):500 Copy/ml Rhinovirus: 500 Kwafi/ml mutum metapneumovirus: 500 kwafi/ml |
Musamman | Binciken giciye-reactivity ya nuna cewa babu wani haɗin kai tsakanin wannan kit da enterovirus A, B, C, D, cutar epstein-barr, cutar kyanda, kwayar cutar ɗan adam, cytomegalovirus, rotavirus, norovirus, mumps virus, varicella-herpes zoster virus, bordetella pertussis, streptococcus pyogenes, mycobacterium tarin fumigatus, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans da ɗan adam genomic nucleic acid. |
Abubuwan da ake Aiwatar da su | Abubuwan da aka Aiwatar da Biosystems 7500 Tsarin PCR na GaskiyaAbubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-TimeQuantStudio®5 Tsarin PCR na Gaskiya SLAN-96P Tsarin PCR na Gaskiya (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Tsarin PCR na ainihi, Tsarin Gano PCR na LineGene 9600 Plus (FQD-96A, fasahar Hangzhou Bioer) MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Tsarin PCR na Gaskiya BioRad CFX Opus 96 Tsarin PCR na Gaskiya |
Gudun Aiki
Zabin 1.
Shawarar hakar reagent: Macro & Micro-Test Samfurin Sakin Reagent (HWTS-3005-8) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ya kamata a aiwatar da hakar a cikin tsananin daidai da umarnin.
Zabin 2.
Nasihar hakar reagent: Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) da Macro & Micro-Test Atomatik Nucleic Acid Extractor ( HWTS-3006C, HWTS-3006B) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., hakar ya kamata a gudanar bisa ga umarnin sosai.Adadin da aka ba da shawarar shine 80μL.
Zabin 3.
Shawarar hakar reagent: Nucleic Acid hakar ko Tsarkake Kit (YDP315) ta Tiangen Biotech(Beijing) Co., Ltd., da hakar ya kamata a gudanar bisa ga umarnin sosai.Adadin da aka ba da shawarar shine 100μL.