Ire-iren Cututtuka 19 na Nucleic Acid

Takaitaccen Bayani:

Ana amfani da wannan kayan aiki don gano SARS-CoV-2, ƙwayar cutar mura A, ƙwayar cutar mura B, adenovirus, ƙwayar cutar mycoplasma pneumoniae, ƙwayar cutar chlamydia pneumoniae, ƙwayar cutar numfashi da ƙwayar cutar parainfluenza (Ⅰ, II, III, IV) a cikin samfuran swabs na makogwaro da maniyyi, ƙwayar cutar metapneumovirus ta ɗan adam, ƙwayar cutar haemophilus, ƙwayar cutar streptococcus pneumoniae, klebsiella pneumoniae, staphylococcus aureus, pseudomonas aeruginosa, legionella pneumophila da acinetobacter baumannii.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

Nau'ikan Kayan Gano Kwayoyin Nucleic Acid na HWTS-RT069A-19 (Fluorescence PCR)

Tashar

Sunan Tashar

Hu19 Reaction Buffer A

Hu19 Reaction Buffer B

Hu19 Reaction Buffer C

Hu19 Reaction Buffer D

Hu19 Reaction Buffer E

Hu19 Reaction Buffer F

Tashar FAM

SARS-CoV-2

HADV

HPIV Ⅰ

CPN

SP

HI

Tashar VIC/HEX

Sarrafa Cikin Gida

Sarrafa Cikin Gida

HPIV Ⅱ

Sarrafa Cikin Gida

Sarrafa Cikin Gida

Sarrafa Cikin Gida

Tashar CY5

IFV A

MP

HPIV Ⅲ

ƙafa

PA

KPN

Tashar ROX

IFV B

RSV

HPIV Ⅳ

HMPV

SA

Aba

Sigogi na Fasaha

Ajiya

≤-18℃ Cikin duhu

Tsawon lokacin shiryawa

Watanni 12

Nau'in Samfuri

Samfuran swab na oropharyngeal,Samfuran swab na maniyyi

CV

≤5.0%

Ct

≤40

LoD

Kwafi 300/mL

Takamaiman Bayani

Binciken da aka yi kan amsawar ƙwayoyin cuta ya nuna cewa babu wani haɗin gwiwa tsakanin wannan kayan aiki da rhinovirus A, B, C, enterovirus A, B, C, D, cutar metapneumovirus ta ɗan adam, cutar epstein-barr, cutar kyanda, cutar cytomegalovirus ta ɗan adam, rotavirus, norovirus, cutar mumps, cutar varicella-band herpes zoster, cutar bordetella pertussis, streptococcus pyogenes, cutar tarin fuka ta mycobacterium, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jiravecii, cryptococcus neoformans da kuma kwayar halittar ɗan adam.

Kayan Aiki Masu Amfani:

Tsarin PCR na Zamani na Aiyuka 7500

Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500

Tsarin PCR na Ainihin Lokaci na QuantStudio®5

Tsarin PCR na SLAN-96P na Gaskiya

Tsarin PCR na LightCycler®480 na Ainihin Lokaci

Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci

Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci

Tsarin PCR na BioRad CFX96 na Ainihin Lokaci

Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci

Gudun Aiki

Zaɓi na 1.

Shawarar da aka ba da shawarar cirewa: Kit ɗin Macro & Micro-Test Viral DNA/RNA (HWTS-3001, HWTS-3004-32, HWTS-3004-48) da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006).

Zaɓi na 2.

Shawarar sinadarin cirewa: Cire sinadarin Nucleic Acid ko kuma sinadarin tsarkakewa (YDP302) daga Tiangen Biotech(Beijing) Co.,Ltd.


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi