Nau'o'i 28 na Cutar Papilloma ta Mutum Mai Haɗari (Typing 16/18) Nucleic Acid
Sunan samfurin
HWTS-CC006A-28 Nau'ikan Kwayar Cutar Papilloma ta Dan Adam Mai Haɗari Mai Yawa (Tura 16/18) Kayan Gano Acid na Nucleic (Fluorescence PCR)
Ilimin Cututtuka
Ciwon daji na mahaifa yana ɗaya daga cikin ciwace-ciwacen da suka fi yawa a cikin mata. Bincike ya nuna cewa kamuwa da cutar HPV mai ɗorewa da kamuwa da cuta da yawa suna ɗaya daga cikin manyan abubuwan da ke haifar da ciwon daji na mahaifa. A halin yanzu, har yanzu ba a sami ingantattun magunguna da aka sani don ciwon daji na mahaifa wanda HPV ke haifarwa ba, don haka ganowa da rigakafin kamuwa da cutar da HPV ke haifarwa da wuri shine mabuɗin hana ciwon daji na mahaifa. Yana da matuƙar muhimmanci a kafa gwajin ganewar asali mai sauƙi, takamaiman kuma mai sauri don gano cutar da maganin cutar kansar mahaifa.
Tashar
| Haɗin Amsa | Tashar | Nau'i |
| PCR-Mix1 | FAM | 18 |
| VIC (HEX) | 16 | |
| ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
| CY5 | Sarrafa Cikin Gida | |
| PCR-Mix2 | FAM | 6, 11, 54, 83 |
| VIC (HEX) | 26, 44, 61, 81 | |
| ROX | 40, 42, 43, 53, 73, 82 | |
| CY5 | Sarrafa Cikin Gida |
Sigogi na Fasaha
| Ajiya | Ruwa: ≤-18℃ |
| Tsawon lokacin shiryawa | Watanni 12 |
| Nau'in Samfuri | Swab na mahaifa, Swab na farji, Fitsari |
| Ct | ≤28 |
| CV | <5.0% |
| LoD | Kwafi 300/mL |
| Kayan Aiki Masu Amfani | Tsarin PCR na Zamani na Aiyuka 7500 Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500 QuantStudio®Tsarin PCR guda 5 na Ainihin Lokaci Tsarin PCR na SLAN-96P na Gaskiya LightCycler®Tsarin PCR na 480 na Ainihin Lokaci Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci Tsarin PCR na BioRad CFX96 na Ainihin Lokaci Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci |
Gudun Aiki
Shawarar da aka ba da shawarar cirewa: Kit ɗin Macro & Micro-Test Viral DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ƙara 200μL na saline na yau da kullun don sake dasa pellet a mataki na 2.1, sannan a gudanar da cirewar bisa ga umarnin amfani da wannan reagent na cirewa. Girman fitarwa da aka ba da shawarar shine 80μL.
Shawarar da aka ba da shawarar cirewa: QIAamp DNA Mini Kit (51304) ko Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Ƙara 200μL na saline na yau da kullun don sake dasa pellet a mataki na 2.1, sannan a gudanar da cirewar bisa ga umarnin amfani da wannan reagent na cirewa. Yawan samfurin da aka cire duk 200μL ne, kuma girman fitarwa da aka ba da shawarar shine 100μL.