Nau'o'i 28 na Cutar Papilloma ta Mutum Mai Haɗari (Typing 16/18) Nucleic Acid

Takaitaccen Bayani:

Wannan kayan aikin ya dace da gano nau'ikan ƙwayoyin cuta na papilloma na ɗan adam guda 28 (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) a cikin fitsarin namiji/mace da ƙwayoyin da aka cire daga mahaifar mace. Ana iya rubuta HPV 16/18, sauran nau'ikan ba za a iya rubuta su gaba ɗaya ba, wanda ke ba da hanya mai taimako don ganowa da magance kamuwa da cutar HPV.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

HWTS-CC006A-28 Nau'ikan Kwayar Cutar Papilloma ta Dan Adam Mai Haɗari Mai Yawa (Tura 16/18) Kayan Gano Acid na Nucleic (Fluorescence PCR)

Ilimin Cututtuka

Ciwon daji na mahaifa yana ɗaya daga cikin ciwace-ciwacen da suka fi yawa a cikin mata. Bincike ya nuna cewa kamuwa da cutar HPV mai ɗorewa da kamuwa da cuta da yawa suna ɗaya daga cikin manyan abubuwan da ke haifar da ciwon daji na mahaifa. A halin yanzu, har yanzu ba a sami ingantattun magunguna da aka sani don ciwon daji na mahaifa wanda HPV ke haifarwa ba, don haka ganowa da rigakafin kamuwa da cutar da HPV ke haifarwa da wuri shine mabuɗin hana ciwon daji na mahaifa. Yana da matuƙar muhimmanci a kafa gwajin ganewar asali mai sauƙi, takamaiman kuma mai sauri don gano cutar da maganin cutar kansar mahaifa.

Tashar

Haɗin Amsa Tashar Nau'i
PCR-Mix1 FAM 18
VIC (HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Sarrafa Cikin Gida
PCR-Mix2 FAM 6, 11, 54, 83
VIC (HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Sarrafa Cikin Gida

Sigogi na Fasaha

Ajiya Ruwa: ≤-18℃
Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri Swab na mahaifa, Swab na farji, Fitsari
Ct ≤28
CV <5.0%
LoD Kwafi 300/mL
Kayan Aiki Masu Amfani Tsarin PCR na Zamani na Aiyuka 7500
Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500
QuantStudio®Tsarin PCR guda 5 na Ainihin Lokaci
Tsarin PCR na SLAN-96P na Gaskiya
LightCycler®Tsarin PCR na 480 na Ainihin Lokaci
Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci
Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci
Tsarin PCR na BioRad CFX96 na Ainihin Lokaci
Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci

Gudun Aiki

Shawarar da aka ba da shawarar cirewa: Kit ɗin Macro & Micro-Test Viral DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ƙara 200μL na saline na yau da kullun don sake dasa pellet a mataki na 2.1, sannan a gudanar da cirewar bisa ga umarnin amfani da wannan reagent na cirewa. Girman fitarwa da aka ba da shawarar shine 80μL.
Shawarar da aka ba da shawarar cirewa: QIAamp DNA Mini Kit (51304) ko Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Ƙara 200μL na saline na yau da kullun don sake dasa pellet a mataki na 2.1, sannan a gudanar da cirewar bisa ga umarnin amfani da wannan reagent na cirewa. Yawan samfurin da aka cire duk 200μL ne, kuma girman fitarwa da aka ba da shawarar shine 100μL.


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi