Hepatitis B Virus RNA
Sunan samfur
HWTS-HP007 Hepatitis B Virus RNA Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Qgano matakan HBV-RNA a cikin jini ba tare da izini ba zai iya sa ido sosai kan matakin HBV cccDNA a cikin hanta, kuma a lokaci guda guje wa haifar da babbar illa ga marasa lafiya.Yana da matukar mahimmanci don gano ƙarin kamuwa da cutar hanta B (HBV) kamuwa da cuta da ingantaccen sa ido da tsinkayar janyewar ƙwayoyi na maganin rigakafi na NAs a cikin marasa lafiya na CHB.
Tashoshi
FAM | HBV-RNA |
ROX | Ikon Cikin Gida |
Ma'aunin Fasaha
Adana | ≤-18℃ |
Rayuwar rayuwa | watanni 9 |
Nau'in Samfura | magani |
Tt | ≤42 |
CV | ≤5.0% |
LoD | 100 kwafi/ml |
Musamman | Sakamakon gwajin tsangwama ya nuna cewa babu wani tasiri akan ƙaddarar HBV RNA lokacin da maida hankali na bilirubin a cikin jini bai wuce 168.2μmol / ml ba, yawan haemoglobin da aka samar ta hemolysis bai wuce 130g/L ba, kuma taro na lipids na jini bai wuce 65 mmol/ml ba;babu wani tasiri akan ƙaddarar HBV RNA lokacin da jimlar IgG a cikin jini bai wuce 5mg/mL ba.Sakamakon gwajin amsawa ya nuna cewa babu wani haɗin kai tsakanin wannan kit ɗin da sauran ƙwayoyin cuta ko ƙwayoyin cuta waɗanda nucleic acid suka gano a cikin samfuran jini (cutar cutar hepatitis C, ɗan adam cytomegalovirus, epstein-barr virus, ƙwayoyin cuta na immunodeficiency na ɗan adam, cutar hepatitis A, syphilis. , Human Herpes virus type 6, herpes simplex virus type 1, herpes simplex virus type 2, mura A virus, propionibacterium acnes, staphylococcus aureus, candida albicans) da kwayoyin halittar dan adam;bayan marasa lafiya sun dauki lamivudine, telbivudine, adefovir dipivoxil da entecavir, lokacin da kwayar cutar hepatitis B a cikin jiki ta wuce mafi ƙarancin LoD na kit, har yanzu ana iya gano kit ɗin yadda ya kamata. |
Abubuwan da ake Aiwatar da su | Aiwatar da Tsarin Halitta 7500 Tsarin PCR na GaskiyaAbubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time SLAN-96P Tsarin PCR na Gaskiya (Hongshi Medical Technology Co., Ltd.) |
Gudun Aiki
Zabin 1.
Kwayar cuta ta DNA/RNA Keɓewa Kit (NA007-2) ta GenMag Biotechnology Co., Ltd. Takamaiman matakan hakar don Allah a bi ƙa'idodin koyarwa.
Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za'a iya amfani dashi tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The hakar ya kamata a za'ayi bisa ga umarnin manual, da cire samfurin girma ne 200μL, da shawarar elution girma ne. 80ml ku.