Human Papillomavirus (Nau'i 28) Genotyping
Sunan samfur
HWTS-CC013-Human Papillomavirus (Nau'i 28) Kayan Gane Genotyping (Fluorescence PCR)
Epidemiology
Ciwon daji na mahaifa yana daya daga cikin muggan ciwace-ciwacen da ake samu a cikin mahaifar mata.Binciken da aka yi a baya ya nuna cewa kamuwa da cuta da yawa da kamuwa da cutar papillomavirus na ɗaya daga cikin mahimman abubuwan da ke haifar da kansar mahaifa.A halin yanzu, har yanzu akwai rashin ingantaccen hanyoyin magance cutar ta HPV, don haka gano wuri da wuri da rigakafin cutar HPV na mahaifa shine mabuɗin toshe kansa.Don kafa hanya mai sauƙi, ƙayyadaddun ƙayyadaddun tsarin ganewar asali na etiological yana da mahimmanci a cikin ganewar asibiti na ciwon daji na mahaifa.
Tashoshi
Mai ɗaukar martani | FAM | VIC/HEX | ROX | CY5 |
HPV Genotyping Reaction Buffer 1 | 16 | 18 | / | Ikon cikin gida |
HPV Genotyping Reaction Buffer 2 | 56 | / | 31 | Ikon cikin gida |
HPV Genotyping Reaction Buffer 3 | 58 | 33 | 66 | 35 |
HPV Genotyping Reaction Buffer 4 | 53 | 51 | 52 | 45 |
HPV Genotyping Reaction Buffer 5 | 73 | 59 | 39 | 68 |
HPV Genotyping Reaction Buffer 6 | 6 | 11 | 83 | 54 |
HPV Genotyping Reaction Buffer 7 | 26 | 44 | 61 | 81 |
HPV Genotyping Reaction Buffer 8 | 40 | 43 | 42 | 82 |
Ma'aunin Fasaha
Adana | Ruwa: ≤-18℃ |
Rayuwar rayuwa | watanni 12 |
Nau'in Samfura | Swab Cervical, Farji Swab, Fitsari |
Ct | ≤28 |
CV | ≤5.0% |
LoD | 300 Kwafi/ml |
takamaiman | Duk sakamakon ba daidai ba ne lokacin da aka yi amfani da kit ɗin don gano samfuran da ba na musamman waɗanda ke da halayen giciye tare da shi, gami da ureaplasma urealyticum, chlamydia trachomatis na fili na haihuwa, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella da sauran nau'ikan HP. ta kit. |
Abubuwan da ake Aiwatar da su | Aiwatar da Tsarin Halitta 7500 Tsarin PCR na Gaskiya Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time QuantStudio®5 Tsarin PCR na Gaskiya SLAN-96P Tsarin PCR na Gaskiya LightCycler®480 Tsarin PCR na Gaskiya LineGene 9600 Plus Tsarukan Gane PCR na Gaskiya MA-6000 Mai ƙididdige yawan zafin jiki na ainihi BioRad CFX96 Tsarin PCR na Gaskiya BioRad CFX Opus 96 Tsarin PCR na Gaskiya |
Gudun Aiki
Zabin 1.
Abubuwan da aka ba da shawarar cirewa: Macro & Micro-Test Samfurin Sakin Reagent (HWTS-3005-8)
Zabin 2.
Abubuwan da aka ba da shawarar cirewa: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS- 3006B)