Nau'o'i Tara na Kwayoyin Cutar Numfashi

Takaitaccen Bayani:

Ana amfani da wannan kit ɗin don gano in vitro qualitative ganewar cutar mura A (IFV A), mura B virus (IFVB), ​​novel coronavirus (SARS-CoV-2) , numfashi syncytial virus (RSV), adenovirus (Adv), mutum metapneumovirus (hMPV), rhinovirus (RhI / VII) da kuma parainflu. pneumoniae (MP) nucleic acid a cikin mutum oropharyngeal swab da nasopharyngeal swab samfurori.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

HWTS-RT185A-Irin Kwayoyin Cutar Nukiliya Guda Tara Kayan Gano Acid Na Nucleic (Fluorescence PCR)

Ilimin Cututtuka

Cutar numfashi ita ce nau'in cutar da ta fi yawa a cikin mutane, wadda za ta iya faruwa a kowace jinsi, shekaru da yanki, kuma tana ɗaya daga cikin manyan abubuwan da ke haifar da rashin lafiya da mutuwa a duniya[1]. Kwayoyin cututtuka na numfashi na asibiti na yau da kullum sun hada da mura A virus (IFV A), mura B virus (IFV B), novel coronavirus (SARS-CoV-2), kwayar cutar syncytial na numfashi, adenovirus, mutum metapneumovirus, rhinovirus, parainfluenza virus (I/II/III) da mycoplasma pneumoniae, da dai sauransu.[2,3]Alamomin asibiti da alamun da kamuwa da cutar numfashi ke haifarwa suna kama da juna, amma kamuwa da cutar da cututtuka daban-daban ke haifarwa yana da hanyoyi daban-daban na magani, tasirin magani da kuma yadda cutar ke yaduwa.[4,5]A halin yanzu, manyan hanyoyin gano ƙwayoyin cuta na numfashi a dakin gwaje-gwaje sun haɗa da: ware ƙwayoyin cuta, gano antigen da gano nucleic acid. Wannan kayan aikin yana gano kuma yana gano takamaiman ƙwayoyin cuta na nucleic acid a cikin mutanen da ke da alamun kamuwa da cutar numfashi, tare da sauran sakamakon asibiti da na dakin gwaje-gwaje don taimakawa wajen gano kamuwa da cutar ƙwayoyin cuta ta numfashi.

Tashar

FAM MP nucleic acid
ROX

Sarrafa Cikin Gida

Sigogi na Fasaha

Ajiya

2-8℃

Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri Swab na hanci; Swab na hanci
Ct COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD Kwafi 200/mL
Takamaiman Bayani Reactivity na Cross: Babu wani reactivity tsakanin kit ɗin da ƙwayar cutar Boca, Cytomegalovirus, ƙwayar cutar Epstein-Barr, ƙwayar cutar Herpes simplex, ƙwayar cutar varicella zoster, ƙwayar cutar Mumps, Enterovirus, ƙwayar cutar kyanda, ƙwayar cutar coronavirus ta ɗan adam, SARS Coronavirus, MERS Coronavirus, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tarin fuka, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivary, Moraxella catarrh, Lactobacillus, Corynebacterium, DNA na halittar ɗan adam.

Gwajin tsangwama: Zaɓi mucin (60mg/mL), jinin ɗan adam (50%), benephrin (2mg/mL), hydroxymethazoline (2mg/mL) 2mg/mL), sodium chloride tare da 5% mai kiyayewa (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), fluniacetone (20μg/mL), triamcinolone (2mg/mL), budesonide (1mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL), peramivir (1mg/mL), mupirocin (20mg/mL), tobramycin (0.6mg/mL), oseltamivir (60ng/mL), ribavirin (10mg/L), The Sakamakon ya nuna cewa abubuwan da ke shiga tsakani a cikin taro da ke sama ba su da wani martani ga gano kayan aikin.

Kayan Aiki Masu Amfani An yi amfani da shi don gano nau'in I: Tsarin PCR na Applied Biosystems 7500 Real-Time, QuantStudio®Tsarin PCR guda 5 na Real-Time, Tsarin SLAN-96P na Real-Time (Hongshi Medical Technology Co., Ltd.), Tsarin Gano PCR na Real-Time LineGene 9600 Plus (FQD-96A, fasahar Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Tsarin PCR na Real-Time BioRad CFX96, Tsarin PCR na Real-Time BioRad CFX Opus 96.

An yi amfani da shi ga na'urar gano nau'in II: EudemonTM AIO800 (HWTS-EQ007) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ajiya

2-8℃

Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri Swab na hanci; Swab na hanci
Ct COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD Kwafi 200/mL
Takamaiman Bayani Reactivity na Cross: Babu wani reactivity tsakanin kit ɗin da ƙwayar cutar Boca, Cytomegalovirus, ƙwayar cutar Epstein-Barr, ƙwayar cutar Herpes simplex, ƙwayar cutar varicella zoster, ƙwayar cutar Mumps, Enterovirus, ƙwayar cutar kyanda, ƙwayar cutar coronavirus ta ɗan adam, SARS Coronavirus, MERS Coronavirus, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tarin fuka, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivary, Moraxella catarrh, Lactobacillus, Corynebacterium, DNA na halittar ɗan adam.

Gwajin tsangwama: Zaɓi mucin (60mg/mL), jinin ɗan adam (50%), benephrin (2mg/mL), hydroxymethazoline (2mg/mL) 2mg/mL), sodium chloride tare da 5% mai kiyayewa (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), fluniacetone (20μg/mL), triamcinolone (2mg/mL), budesonide (1mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL), peramivir (1mg/mL), mupirocin (20mg/mL), tobramycin (0.6mg/mL), oseltamivir (60ng/mL), ribavirin (10mg/L), The Sakamakon ya nuna cewa abubuwan da ke shiga tsakani a cikin taro da ke sama ba su da wani martani ga gano kayan aikin.

Kayan Aiki Masu Amfani An yi amfani da shi don gano nau'in I: Tsarin PCR na Applied Biosystems 7500 Real-Time, QuantStudio®Tsarin PCR guda 5 na Real-Time, Tsarin SLAN-96P na Real-Time (Hongshi Medical Technology Co., Ltd.), Tsarin Gano PCR na Real-Time LineGene 9600 Plus (FQD-96A, fasahar Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Tsarin PCR na Real-Time BioRad CFX96, Tsarin PCR na Real-Time BioRad CFX Opus 96.

An yi amfani da shi ga na'urar gano nau'in II: EudemonTM AIO800 (HWTS-EQ007) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Gudun Aiki

Kit ɗin DNA/RNA na Macro & Micro-Test Viral (HWTS-3017) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), da Kit ɗin DNA/RNA na Macro & Micro-Test Viral (HWTS-3017-8) (wanda za a iya amfani da shi tare da Eudemon)TM AIO800 (HWTS-EQ007)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ƙarar samfurin da aka fitar shine 200μL kuma ƙarar fitarwa da aka ba da shawarar shine 150μL.