Nau'u Tara Na Numfashi Virus

Takaitaccen Bayani:

Ana amfani da wannan kit ɗin don gano in vitro qualitative ganewar cutar mura A (IFV A), mura B virus (IFVB), ​​novel coronavirus (SARS-CoV-2) , numfashi syncytial virus (RSV), adenovirus (Adv), mutum metapneumovirus (hMPV), rhinovirus (RhI / VII) da kuma parainflu. pneumoniae (MP) nucleic acid a cikin mutum oropharyngeal swab da nasopharyngeal swab samfurori.


Cikakken Bayani

Tags samfurin

Sunan samfur

HWTS-RT185A-Iri Nau'in Nau'in Kwayoyin cuta Na Numfashi Na'urar Gano Nukiliya Acid (Fluorescence PCR)

Epidemiology

Cutar sankarau ita ce nau’in cutar da aka fi sani da mutane, wacce za ta iya faruwa a kowane jinsi, shekaru da yanki, kuma yana daya daga cikin manyan abubuwan da ke haifar da cututtuka da mutuwa a duniya.[1]. Kwayoyin cututtuka na numfashi na asibiti na yau da kullum sun hada da mura A virus (IFV A), mura B virus (IFV B), novel coronavirus (SARS-CoV-2), kwayar cutar syncytial na numfashi, adenovirus, mutum metapneumovirus, rhinovirus, parainfluenza virus (I/II/III) da mycoplasma pneumoniae, da dai sauransu.[2,3]. Alamomin asibiti da alamun da ke haifar da kamuwa da cutar ta numfashi suna da kama da kamanni, amma kamuwa da cuta ta hanyar ƙwayoyin cuta daban-daban yana da hanyoyin magani daban-daban, tasirin warkewa da kuma yanayin cututtuka.[4,5]. A halin yanzu, manyan hanyoyin binciken dakin gwaje-gwaje na cututtukan numfashi sun haɗa da: warewar ƙwayoyin cuta, gano antigen da gano nucleic acid. Wannan kit ɗin yana ganowa da kuma gano takamaiman ƙwayoyin nucleic acid a cikin mutane masu alamun kamuwa da cutar numfashi, tare da sauran sakamakon asibiti da dakin gwaje-gwaje don taimakawa wajen gano kamuwa da cutar ƙwayar cuta ta numfashi.

Tashoshi

FAM MP nucleic acid
ROX

Ikon Cikin Gida

Ma'aunin Fasaha

Adana

2-8 ℃

Rayuwar rayuwa watanni 12
Nau'in Samfura Oropharyngeal swab; Nasopharyngeal swab
Ct COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD 200 Kwafi/ml
Musamman Reactivity: Babu giciye reactivity tsakanin kit da Boca cutar, Cytomegalovirus, Epstein-Barr cutar, Herpes simplex cutar, varicella zoster Virus, Mumps cutar, Enterovirus, kyanda cutar, coronavirus mutum, SARS Coronavirus, MERS Coronavirus, Rotavirus, Norovirus, Chlamydia pneumoniae, pneptococcusiella, Streptococcusiella. ciwon huhu, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus mura, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tarin fuka, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptoanscoccus nephritis. catarrh, Lactobacillus, Corynebacterium, DNA na ɗan adam.

Gwajin tsangwama: Zaɓi mucin (60mg/ml), jinin mutum (50%), benephrin (2mg/mL), hydroxymethazoline (2mg/mL) 2mg/mL), sodium chloride tare da 5% preservative (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mtone), 20mg/mtone (L) (2mg/ml), budesonide (1mg/ml), mometasone (2mg/ml), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL), peramivir (1mg/mL), mupirom (1mg/mL), mupirom (20mg/mL), mupiromL0 (20mg) oseltamivir (60ng/mL), ribavirin (10mg/L), Sakamakon ya nuna cewa abubuwan da ke shiga tsakani a cikin abin da ke sama ba su da wani tasiri mai mahimmanci ga gano kayan.

Abubuwan da ake Aiwatar da su Ana iya amfani da shi don buga I detection reagent: Applied Biosystems 7500 Real-Time PCR Systems, QuantStudio®5 Real-Time PCR Systems, SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.), LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, Hangzhou Bioer fasaha), MA-6000 Real-Time Quantitative Thermal Cycler), Co.Rzhou Cycler Real-Time Real Time (Suzhou Cycler) Tsarin PCR, BioRad CFX Opus 96 Tsarin PCR na Gaskiya.

Mai dacewa don nau'in ganowa na II: EudemonTM AIO800 (HWTS-EQ007) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Adana

2-8 ℃

Rayuwar rayuwa watanni 12
Nau'in Samfura Oropharyngeal swab; Nasopharyngeal swab
Ct COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD 200 Kwafi/ml
Musamman Reactivity: Babu giciye reactivity tsakanin kit da Boca cutar, Cytomegalovirus, Epstein-Barr cutar, Herpes simplex cutar, varicella zoster Virus, Mumps cutar, Enterovirus, kyanda cutar, coronavirus mutum, SARS Coronavirus, MERS Coronavirus, Rotavirus, Norovirus, Chlamydia pneumoniae, pneptococcusiella, Streptococcusiella. ciwon huhu, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus mura, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tarin fuka, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptoanscoccus nephritis. catarrh, Lactobacillus, Corynebacterium, DNA na ɗan adam.

Gwajin tsangwama: Zaɓi mucin (60mg/ml), jinin mutum (50%), benephrin (2mg/mL), hydroxymethazoline (2mg/mL) 2mg/mL), sodium chloride tare da 5% preservative (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mtone), 20mg/mtone (L) (2mg/ml), budesonide (1mg/ml), mometasone (2mg/ml), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL), peramivir (1mg/mL), mupirom (1mg/mL), mupirom (20mg/mL), mupiromL0 (20mg) oseltamivir (60ng/mL), ribavirin (10mg/L), Sakamakon ya nuna cewa abubuwan da ke shiga tsakani a cikin abin da ke sama ba su da wani tasiri mai mahimmanci ga gano kayan.

Abubuwan da ake Aiwatar da su Ana iya amfani da shi don buga I detection reagent: Applied Biosystems 7500 Real-Time PCR Systems, QuantStudio®5 Real-Time PCR Systems, SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.), LineGene 9600 Plus Real-Time PCR Detection Systems (FQD-96A, Hangzhou Bioer fasaha), MA-6000 Real-Time Quantitative Thermal Cycler), Co.Rzhou Cycler Real-Time Real Time (Suzhou Cycler) Tsarin PCR, BioRad CFX Opus 96 Tsarin PCR na Gaskiya.

Mai dacewa don nau'in ganowa na II: EudemonTM AIO800 (HWTS-EQ007) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Gudun Aiki

Macro & Micro-Test Viral DNA / RNA Kit (HWTS-3017) (wanda za'a iya amfani dashi tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), da Macro & Micro-Test Viral DNA / RNA Kit (HWTS-3017-8)TM AIO800 (HWTS-EQ007)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Girman samfurin da aka fitar shine 200μL kuma ƙimar da aka ba da shawarar shine 150μL.


  • Na baya:
  • Na gaba:

  • Ku rubuta sakonku anan ku aiko mana