Chlamydia Trachomatis, Neisseria Gonorrhea da Trichomonas vaginalis.
Sunan samfur
HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Chlamydia trachomatis (CT) wani nau'in microorganism ne na prokaryotic wanda ke da matsananciyar parasitic a cikin sel eukaryotic.Chlamydia trachomatis an raba shi zuwa AK serotypes bisa hanyar serotype.Cututtukan Urogenital galibi suna faruwa ne ta hanyar trachoma bioological variant DK serotypes, kuma maza galibi suna bayyana a matsayin urethritis, wanda za'a iya samun sauki ba tare da magani ba, amma yawancinsu suna zama na dindindin, lokaci-lokaci, kuma ana iya haɗa su da epididymitis, proctitis, da dai sauransu.
Tashoshi
FAM | Chlamydia trachomatis |
ROX | Neisseria gonorrhea |
CY5 | Trichomonal vaginitis |
VIC/HEX | Ikon Cikin Gida |
Ma'aunin Fasaha
Adana | -18 ℃ |
Rayuwar rayuwa | watanni 12 |
Nau'in Samfura | Swab na mahaifar mace,swab na mace,Namiji na urethra swab |
Ct | ≤38 |
CV | <5% |
LoD | 400Kwafi/ml |
Musamman | Babu wani giciye-reactivity tare da sauran STD kamuwa da cuta pathogens a waje da ganewa kewayon gwajin kit, irin su Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, da dai sauransu. |
Abubuwan da ake Aiwatar da su | Aiwatar da Tsarin Halitta 7500 Tsarin PCR na Gaskiya Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time QuantStudio®5 Tsarin PCR na Gaskiya SLAN-96P Tsarin PCR na Gaskiya LightCycler®480 Real-Time PCR tsarin LineGene 9600 Plus Tsarin Gane PCR na Gaskiya MA-6000 Mai ƙididdige yawan zafin jiki na ainihi BioRad CFX96 Tsarin PCR na Gaskiya BioRad CFX Opus 96 Tsarin PCR na Gaskiya |
Gudun Aiki
Zabin 1.
Shawarar hakar reagent: Pipette 1mL na samfurin da za a gwada zuwa 1.5mL na DNA-free centrifuge tube, centrifuge a 12000rpm na 3 minutes, jefar da supernatant da kiyaye hazo.Ƙara 200µL na saline na al'ada zuwa hazo don sake dawowa.Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (wanda za'a iya amfani dashi tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The hakar ya kamata a yi bisa ga umarnin don amfani.Ƙarfin samfurin da aka fitar shine 200µL, kuma ƙimar da aka ba da shawarar shine 80µL.
Zabin 2.
Nasihar hakar reagent: Nucleic Acid Extraction ko Tsabtace Kit (YDP302).Ya kamata a aiwatar da hakar sosai bisa ga umarnin don amfani.Adadin da aka ba da shawarar shine 80µL.