Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis

Takaitaccen Bayani:

An yi nufin wannan kayan aikin ne don gano Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) a cikin in vitro.kumaCiwon farji na Trichomonal (TV) a cikin swab na fitsari na maza, swab na mahaifa na mata, da samfuran swab na farji na mata, kuma yana taimakawa wajen ganowa da magance marasa lafiya da ke fama da cututtukan hanji.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)

Ilimin Cututtuka

Chlamydia trachomatis (CT) wani nau'in ƙwayoyin cuta ne na prokaryotic wanda ke da matuƙar kama da ƙwayoyin cuta a cikin ƙwayoyin eukaryotic. An raba Chlamydia trachomatis zuwa nau'ikan AK bisa ga hanyar serotype. Yawancin cututtukan da ke shafar tsarin urogenital suna faruwa ne ta hanyar trachoma biological variant DK serotypes, kuma maza galibi suna bayyana a matsayin urethritis, wanda za a iya rage shi ba tare da magani ba, amma yawancinsu suna zama na yau da kullun, suna ta'azzara lokaci-lokaci, kuma ana iya haɗa su da epididymitis, proctitis, da sauransu.

Tashar

FAM Chlamydia trachomatis
ROX Neisseria gonorrhoeae
CY5 Ciwon farji na Trichomonal
VIC/HEX Sarrafa Cikin Gida

Sigogi na Fasaha

Ajiya

-18℃

Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri Swab na mahaifa na mace,Mace ta farji swab,Swab na fitsarin maza
Ct ≤38
CV <5%
LoD 400Kwafi/mL
Takamaiman Bayani Babu wani haɗin gwiwa tsakanin wasu ƙwayoyin cuta masu kamuwa da cutar STD a waje da kewayon gano ƙwayoyin cuta na kayan gwajin, kamar Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, da sauransu.
Kayan Aiki Masu Amfani Tsarin PCR na Zamani na Aiyuka 7500

Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500

QuantStudio®Tsarin PCR guda 5 na Ainihin Lokaci

Tsarin PCR na SLAN-96P na Gaskiya

LightCycler®Tsarin PCR na 480 na Ainihin Lokaci

Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci

Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci

Tsarin PCR na BioRad CFX96 na Ainihin Lokaci

Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci

Gudun Aiki

Zaɓi na 1.

Shawarar cirewa: Pipette 1mL na samfurin da za a gwada a cikin bututun centrifuge mara DNase/RNase 1.5mL, centrifuge a 12000rpm na minti 3, a jefar da ruwan da ke cikinsa sannan a ajiye ruwan da ke cikinsa. A ƙara 200µL na saline na yau da kullun a cikin ruwan da ke cikinsa don sake tsayawa. Kit ɗin DNA/RNA na Macro & Micro-Test General (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ya kamata a yi cirewar bisa ga umarnin amfani. Girman samfurin da aka cire shine 200µL, kuma girman fitarwa da aka ba da shawarar shine 80µL.

Zaɓi na 2.

Shawarar sinadarin cirewa: Kayan cirewa ko kuma kayan tsarkakewa na Nucleic Acid (YDP302). Ya kamata a yi cirewar ne bisa ga umarnin amfani. Girman fitar da ruwa da aka ba da shawarar shine 80µL.


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi