Chlamydia Trachomatis, Neisseria Gonorrhea da Trichomonas vaginalis.
Sunan samfur
HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Chlamydia trachomatis (CT) wani nau'in microorganism ne na prokaryotic wanda ke da matsananciyar parasitic a cikin sel eukaryotic. Chlamydia trachomatis an raba shi zuwa AK serotypes bisa hanyar serotype. Cututtukan Urogenital galibi suna faruwa ne ta hanyar trachoma bioological variant DK serotypes, kuma maza galibi suna bayyana a matsayin urethritis, wanda za'a iya samun sauki ba tare da magani ba, amma yawancinsu suna zama na dindindin, lokaci-lokaci, kuma ana iya haɗa su da epididymitis, proctitis, da dai sauransu.
Tashoshi
FAM | Chlamydia trachomatis |
ROX | Neisseria gonorrhea |
CY5 | Trichomonal vaginitis |
VIC/HEX | Ikon Cikin Gida |
Ma'aunin Fasaha
Adana | -18 ℃ |
Rayuwar rayuwa | watanni 12 |
Nau'in Samfura | Swab na mahaifar mace,swab na mace,Namiji na urethra swab |
Ct | ≤38 |
CV | <5% |
LoD | 400Kwafi/ml |
Musamman | Babu wani giciye-reactivity tare da sauran STD kamuwa da cuta pathogens a waje da ganewa kewayon gwajin kit, irin su Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex cutar irin 1, Herpes simplex virus type 2, Candida albicans, da dai sauransu. |
Abubuwan da ake Aiwatar da su | Aiwatar da Tsarin Halitta 7500 Tsarin PCR na Gaskiya Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time QuantStudio®5 Tsarin PCR na Gaskiya SLAN-96P Tsarin PCR na Gaskiya LightCycler®480 Real-Time PCR tsarin LineGene 9600 Plus Tsarin Gane PCR na Gaskiya MA-6000 Mai ƙididdige yawan zafin jiki na ainihi BioRad CFX96 Tsarin PCR na Gaskiya BioRad CFX Opus 96 Tsarin PCR na Gaskiya |
Gudun Aiki
Zabin 1.
Shawarar hakar reagent: Pipette 1mL na samfurin da za a gwada zuwa 1.5mL na DNA-free tube centrifuge tube, centrifuge a 12000rpm na 3 minutes, jefar da supernatant da kiyaye hazo. Ƙara 200µL na saline na al'ada zuwa hazo don sake dawowa. Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (wanda za'a iya amfani dashi tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C) da MacroB06C, Micro-Test Med-Tech Co., Ltd. Ya kamata a yi hakar bisa ga umarnin don amfani. Girman samfurin da aka fitar shine 200µL, kuma ƙarar da aka ba da shawarar shine 80µL.
Zabin 2.