Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Sunan samfurin
Chlamydia Trachomatis, Neisseria Gonorrhoeae da Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Ilimin Cututtuka
Chlamydia trachomatis (CT) wani nau'in ƙwayoyin cuta ne na prokaryotic wanda ke da matuƙar kama da ƙwayoyin cuta a cikin ƙwayoyin eukaryotic. An raba Chlamydia trachomatis zuwa nau'ikan AK bisa ga hanyar serotype. Yawancin cututtukan da ke shafar tsarin urogenital suna faruwa ne ta hanyar trachoma biological variant DK serotypes, kuma maza galibi suna bayyana a matsayin urethritis, wanda za a iya rage shi ba tare da magani ba, amma yawancinsu suna zama na yau da kullun, suna ta'azzara lokaci-lokaci, kuma ana iya haɗa su da epididymitis, proctitis, da sauransu.
Tashar
| FAM | Chlamydia trachomatis |
| ROX | Neisseria gonorrhoeae |
| CY5 | Ciwon farji na Trichomonal |
| VIC/HEX | Sarrafa Cikin Gida |
Sigogi na Fasaha
| Ajiya | -18℃ |
| Tsawon lokacin shiryawa | Watanni 12 |
| Nau'in Samfuri | Swab na mahaifa na mace,Mace ta shafa farji,Swab na fitsarin maza |
| Ct | ≤38 |
| CV | <5% |
| LoD | 400Kwafi/mL |
| Takamaiman Bayani | Babu wani haɗin gwiwa tsakanin wasu ƙwayoyin cuta masu kamuwa da cutar STD a waje da kewayon gano ƙwayoyin cuta na kayan gwajin, kamar Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, da sauransu. |
| Kayan Aiki Masu Amfani | Tsarin PCR na Zamani na Aiyuka 7500 Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500 QuantStudio®Tsarin PCR guda 5 na Ainihin Lokaci Tsarin PCR na SLAN-96P na Lokaci na Gaskiya LightCycler®Tsarin PCR na 480 na Ainihin Lokaci Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci Tsarin PCR na BioRad CFX96 na Ainihin Lokaci Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci |
Tsarin aiki
Ana buƙatar reagent amma ba a bayar da su ba
Kit ɗin DNA/RNA na Macro & Micro-Gwaji na Janar (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (wanda za a iya amfani da shi tare da Macro & Micro-Gwaji Mai Cire Acid na Atomatik (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Gwaji Med-Tech Co., Ltd., Kit ɗin Cire Acid na Nucleic (YDP302).
Ana buƙatar kayan amfani amma ba a bayar da su ba
1.5mL na bututun centrifuge mara DNase/RNase, Tips mara DNase/RNase, centrifuge na tebur, mahaɗin juyawa na tebur.