Ureaplasma Parvum Nucleic Acid

Takaitaccen Bayani:

Wannan kayan aikin ya dace da gano Ureaplasma Parvum (UP) a cikin samfuran fitar da fitsarin maza da mata daga cikin mahaifa, kuma yana taimakawa wajen ganowa da kuma magance marasa lafiya da ke dauke da cutar Ureaplasma parvum.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

Kayan Gano Acid na Nucleic na HWTS-UR046-Ureaplasma (PCR mai haske)

Ilimin Cututtuka

Nau'in Ureaplasma da ke da alaƙa da cutar ɗan adam a halin yanzu an raba su zuwa ƙungiyoyin halittu guda 2 da nau'ikan serotypes guda 14. Rukunin Biogroup Ⅰ shine Ureaplasma urealyticum, wanda ya haɗa da nau'ikan serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, da 13. Rukunin Biogroup Ⅱ shine Ureaplasma parvum, wanda ya haɗa da nau'ikan serotypes: 1, 3, 6, 14. Ureaplasma wani nau'in ƙwayoyin cuta ne ko kuma ƙwayoyin cuta da ke haifar da cututtuka masu yaɗuwa a cikin tsarin genitourinary. Baya ga haifar da cututtukan genitourinary, mata masu kamuwa da cutar Ureaplasma suma suna da yuwuwar aika cutar ga abokan hulɗarsu ta jima'i. Cutar Ureaplasma kuma tana ɗaya daga cikin mahimman abubuwan da ke haifar da rashin haihuwa. Idan mata masu juna biyu suka kamu da cutar Ureaplasma, hakan na iya haifar da fashewar membranes da wuri, haihuwa da wuri, ciwon numfashi na jarirai, kamuwa da cutar bayan haihuwa da sauran mummunan sakamako na ciki, waɗanda ke buƙatar kulawa sosai.

Sigogi na Fasaha

Ajiya

-18℃

Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri hanyar fitsari ta maza, hanyar haihuwa ta mata
Ct ≤38
CV <5.0%
LoD Kwafi 400/mL
Kayan Aiki Masu Amfani Yana aiki don gano nau'in I:

Tsarin PCR na Zamani na 7500 da aka yi amfani da su,

QuantStudio®Tsarin PCR guda 5 na Ainihin Lokaci,

Tsarin PCR na SLAN-96P na Gaskiya (Hongshi Medical Technology Co., Ltd.),

Tsarin Gano PCR na Layi na 9600 Plus na Gaskiya (FQD-96A, fasahar Hangzhou Bioer),

Mai Keke Mai Yawan Zafi na MA-6000 na Ainihin Lokaci (Suzhou Molarray Co., Ltd.),

Tsarin PCR na BioRad CFX96 na Gaskiya,

Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci.

Yana aiki ga na'urar gano nau'in II:

EudemonTMAIO800 (HWTS-EQ007) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Gudun Aiki

Kit ɗin DNA/RNA na Macro & Micro-Test Viral (HWTS-3017) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), da Kit ɗin DNA/RNA na Macro & Micro-Test Viral (HWTS-3017-8) (wanda za a iya amfani da shi tare da Eudemon)TM AIO800 (HWTS-EQ007)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ƙarar samfurin da aka fitar shine 200μL kuma ƙarar fitarwa da aka ba da shawarar shine 150μL.


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi