mura A/B

Takaitaccen Bayani:

Ana amfani da wannan kit ɗin don gano ƙimar ƙwayar cutar mura A/B nucleic acid a cikin samfuran swab na oropharyngeal na ɗan adam a cikin vitro.


Cikakken Bayani

Tags samfurin

Sunan samfur

HWTS-RT003A Murar A/B Kayan Gano Acid Nucleic Acid (Fluorescence PCR)

Epidemiology

Abincin da cutar cuta cuta ce ta cutar cututtukan cututtukan mahaifa, tare da substepes da yawa kamar H1N1 da H3N2, waɗanda ke da haɗari ga maye gurbinsu sun barke a duniya.Canjin Antigenic yana nufin maye gurbin kwayar cutar mura A, wanda ke haifar da fitowar sabon nau'in subtype.Kwayoyin cutar mura B sun kasu zuwa manyan zuriya biyu, Yamagata da Victoria.Kwayoyin cutar mura B kawai suna da drift na antigenic, kuma suna gujewa sa ido da kawar da tsarin garkuwar jikin ɗan adam ta hanyar maye gurbinsu.Duk da haka, yawan juyin halittar kwayar cutar mura B yana da hankali fiye da na mura A, kuma cutar ta mura na iya haifar da kamuwa da kwayar cutar ta numfashi ta mutum kuma ta haifar da annoba.

Tashoshi

FAM IFV A
ROX

Ikon Cikin Gida

VIC/HEX Farashin B

Ma'aunin Fasaha

Adana

≤-18℃

Rayuwar rayuwa watanni 9
Nau'in Samfura oropharyngeal swab
Ct ≤28
CV ≤5.0%
LoD IFV A: 500 Kwafi/ml, IFV B: 500 Kwafi/ml
Musamman 1. Cross-reactivity: babu wani giciye reactivity tsakanin wannan kit da adenovirus type 3, 7, mutum coronavirus SARSr-CoV, MERSr-CoV, HCoV-OC43, HCoV-229E, HCoV-HKU1, da HCoV-NL63, cytomegalovirus, enterovirus, parainfluenza cutar, cutar kyanda, cutar kyanda, mutum metapneumovirus, cutar mumps, numfashi syncytial virus type B, rhinovirus, bordetella pertussis, chlamydia ciwon huhu, corynebacterium, escherichia coli, haemophilus mura, jactobaculrlenthabacteria, myraxella, pneumonia, pneumonia. e, neisseria meningitidis .

2. Gwajin tsangwama: An zaɓi abubuwan da ke shiga tsakani a matsayin mucin (60mg / mL), jinin mutum, oxymetazoline (2mg / mL), sulfur (10%), beclomethasone (20mg / mL), dexamethasone (20mg / mL), flunisolide ( 20μg/mL), triamcinolone (2mg/mL), budesonide (1mg/ml), mometasone (2mg/mL), fluticasone (2mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL). , azithromycin (1mg/L), cephalosporin (40μg/mL), mupirocin (20mg/mL), tobramycin (0.6mg/ml), oseltamivir phosphate (60ng/mL), ribavirin (10mg/L), da sakamakon ya nuna. cewa abubuwan da ke shiga tsakani tare da abubuwan da ke sama ba su da wani tasiri mai tsangwama ga gano kayan.

Abubuwan da ake Aiwatar da su Aiwatar da Tsarin Halitta 7500 Tsarin PCR na Gaskiya

Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time

QuantStudio®5 Tsarin PCR na Gaskiya

SLAN-96P Tsarin PCR na Gaskiya (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Real-Time PCR tsarin

Tsarin Gano PCR na LineGene 9600 Plus (FQD-96A, fasahar Hangzhou Bioer)

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 Tsarin PCR na Gaskiya da BioRad CFX Opus 96 Tsarin PCR na Gaskiya

Gudun Aiki

Zabin 1.

Shawarwari reagents hakar: Macro & Micro-Test Janar DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za a iya amfani da tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The hakar ya kamata a gudanar bisa ga IFU.Girman samfurin hakar shine200 μL.Adadin da aka ba da shawarar shine 80μL.

Zabin 2.

Abubuwan da aka ba da shawarar hakar reagents: Macro & Micro-Test Samfurin Sakin Reagent (HWTS-3005-8).Ya kamata a gudanar da hakar bisa ga IFU.

Zabin 3.

Abubuwan da aka ba da shawarar cirewa: Nucleic Acid Extraction ko Kit ɗin Tsafta (YDP315-R).Ya kamata a gudanar da hakar bisa ga IFU.Girman samfurin hakar shine 140μL.Adadin da aka ba da shawarar shine 60μL.


  • Na baya:
  • Na gaba:

  • Ku rubuta sakonku anan ku aiko mana