Mycoplasma Hominis Nucleic Acid

Takaitaccen Bayani:

Wannan kit ɗin ya dace don gano ƙimar Mycoplasma hominis (MH) a cikin ma'aunin fitsari na maza da samfuran ɓoyewar al'aurar mata.


Cikakken Bayani

Tags samfurin

Sunan samfur

HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Gane Kit (Fluorescence PCR)

Epidemiology

Cututtukan da ake samu ta hanyar jima'i (STDs) har yanzu suna daya daga cikin muhimman abubuwan da ke barazana ga tsaron lafiyar jama'a a duniya, wanda zai iya haifar da rashin haihuwa, haihuwa da haihuwa, ciwon tumorigenesis da matsaloli daban-daban.Mycoplasma hominis yana wanzu a cikin sashin genitourinary kuma yana iya haifar da martani mai kumburi a cikin sashin genitourinary.Ciwon MH na sashin genitourinary zai iya haifar da cututtuka irin su urethritis marasa gonococcal, epididymitis, da dai sauransu, da kuma tsakanin mata, wanda zai iya haifar da kumburin tsarin haihuwa wanda ke yadawa a kan cervix.A lokaci guda kuma, ƙwayar cuta ta MH ta yau da kullum ita ce salpingitis, kuma ƙananan adadin marasa lafiya na iya samun endometritis da ciwon kumburi na pelvic.

Tashoshi

FAM MH manufa
VIC(HEX) Ikon Cikin Gida

Ma'aunin Fasaha

Adana Liquid: ≤-18 ℃ A cikin duhu
Rayuwar rayuwa watanni 12
Nau'in Samfura kumburin urethra, sirrin mahaifa
Ct ≤38
CV 5.0%
LoD 1000 Kwafi/ml
Musamman Babu wani giciye-reactivity tare da sauran STD kamuwa da cuta pathogens, wanda ke waje da ganewa kewayon, kuma babu giciye-reactivity tare da chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhea, neisseria gonorrhea, mycoplasma genitalium, herpes simplex cutar irin 1, herpes simplex virus type 2. , da dai sauransu.
Abubuwan da ake Aiwatar da su Zai iya dacewa da kayan aikin PCR na yau da kullun akan kasuwa.

Abubuwan da aka Aiwatar da Tsarin Halittu 7500 Tsarin PCR Mai Saurin Real-Time

QuantStudio®5 Tsarin PCR na Gaskiya

SLAN-96P Tsarin PCR na Gaskiya

LightCycler®480 Tsarin PCR na Gaskiya

LineGene 9600 Plus Tsarin Gane PCR na Gaskiya

MA-6000 Mai ƙididdige yawan zafin jiki na ainihi

BioRad CFX96 Tsarin PCR na Gaskiya

BioRad CFX Opus 96 Tsarin PCR na Gaskiya

Gudun Aiki

Zabin 1.

Nasihar hakar reagent: Macro & Micro-Test Samfurin Sakin Reagent (HWTS-3005-8).Ya kamata a gudanar da hakar a cikin tsauraran umarni.

Zabin 2.

Shawarar hakar reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za a iya amfani da tare da Macro & Micro-Test Atomatik Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. The hakar ya kamata a tsananin gudanar bisa ga umarnin.Adadin da aka ba da shawarar ya kamata ya zama 80 μL.

Zabin 3.

Shawarar hakar reagent: Nucleic Acid hakar ko tsarkakewa Reagent (YDP302) ta Tiangen Biotech (Beijing) Co., Ltd.


  • Na baya:
  • Na gaba:

  • Ku rubuta sakonku anan ku aiko mana