Mycoplasma Hominis Nucleic Acid

Takaitaccen Bayani:

Wannan kayan aikin ya dace da gano ƙwayoyin cuta na Mycoplasma hominis (MH) a cikin fitsarin maza da kuma samfuran fitar da maniyyi daga al'aurar mace.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan samfurin

Kayan Gano Acid na HWTS-UR004A-Mycoplasma Hominis (Fluorescence PCR)

Ilimin Cututtuka

Cututtukan da ake kamuwa da su ta hanyar jima'i (STDs) har yanzu suna ɗaya daga cikin manyan barazanar da ke barazana ga lafiyar jama'a a duniya, wanda zai iya haifar da rashin haihuwa, haihuwar tayi da wuri, ciwon daji da kuma matsaloli daban-daban masu tsanani. Mycoplasma hominis yana wanzuwa a cikin tsarin genitourinary kuma yana iya haifar da martanin kumburi a cikin tsarin genitourinary. Cutar MH ta tsarin genitourinary na iya haifar da cututtuka kamar urethritis mara gonococcal, epididymitis, da sauransu, kuma a tsakanin mata, wanda zai iya haifar da kumburi na tsarin haihuwa wanda ke yaɗuwa a tsakiya a kan mahaifa. A lokaci guda, matsalar da ake samu ta kamuwa da cutar MH ita ce salpingitis, kuma ƙaramin adadin marasa lafiya na iya samun endometritis da cutar kumburin ƙashin ƙugu.

Tashar

FAM MH manufa
VIC (HEX) Sarrafa Cikin Gida

Sigogi na Fasaha

Ajiya Ruwa: ≤-18℃ A cikin duhu
Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri fitar fitsari daga urethra, fitar da mahaifa
Ct ≤38
CV <5.0%
LoD Kwafi 1000/mL
Takamaiman Bayani Babu wani haɗin gwiwa da wasu ƙwayoyin cuta masu kamuwa da cutar STD, waɗanda ba su cikin kewayon gano cutar, kuma babu haɗin gwiwa da ke tattare da chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus type 1, herpes simplex virus type 2, da sauransu.
Kayan Aiki Masu Amfani Zai iya daidaita manyan kayan aikin PCR masu haske a kasuwa.

Tsarin PCR Mai Sauri na Ainihin Lokaci Mai Amfani da Biosystems 7500

Tsarin PCR na Ainihin Lokaci na QuantStudio®5

Tsarin PCR na SLAN-96P na Gaskiya

Tsarin PCR na LightCycler®480 na Ainihin Lokaci

Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci

Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci

Tsarin PCR na BioRad CFX96 na Ainihin Lokaci

Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci

Gudun Aiki

Zaɓi na 1.

Maganin cirewa da aka ba da shawarar: Maganin sake fitar da samfurin Macro & Micro-Test (HWTS-3005-8). Ya kamata a gudanar da cirewar bisa ga umarnin.

Zaɓi na 2.

Shawarar da aka ba da shawarar cirewa: Kit ɗin Macro & Micro-Test Viral DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ya kamata a gudanar da cirewar sosai bisa ga umarnin. Yawan fitar da ruwa da aka ba da shawarar ya kamata ya zama 80 μL.

Zaɓi na 3.

Maganin cirewa da aka ba da shawarar: Maganin cirewa ko tsarkakewa na Nucleic Acid (YDP302) na Tiangen Biotech (Beijing) Co., Ltd.. Ya kamata a gudanar da cirewar bisa ga umarnin kuma girman fitar da ruwa da aka ba da shawarar shine 80µL.


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi