Kit ɗin Gano Acid na Ureaplasma (PCR mai haske)

Takaitaccen Bayani:

Wannan kayan aikin ya dace da gano Ureaplasma urealyticum (UU) a cikin fitsarin maza da samfuran fitar da maniyyi daga al'aurar mace a cikin vitro.


Cikakken Bayani game da Samfurin

Alamun Samfura

Sunan Samfuri

Kit ɗin Gano Acid na Ureaplasma (PCR mai haske)

Ilimin Cututtuka

Ureaplasma urealyticum (UU) ita ce ƙaramar ƙwayar cuta ta prokaryotic da ke rayuwa ba tare da wata cuta ba tsakanin ƙwayoyin cuta da ƙwayoyin cuta, kuma ita ce ƙwayar cuta mai cututtuka wadda ke iya kamuwa da cututtukan al'aura da na mafitsara. Ga maza, tana iya haifar da prostatitis, urethritis, pyelonephritis, da sauransu. Ga mata, tana iya haifar da kumburi a cikin hanyoyin haihuwa kamar vaginitis, cervicitis, da cutar kumburin ƙashin ƙugu. Yana ɗaya daga cikin ƙwayoyin cuta da ke haifar da rashin haihuwa da zubar da ciki. An raba Ureaplasma urealyticum zuwa nau'ikan serotypes 14, waɗanda aka raba zuwa ƙungiyoyi biyu bisa ga halayen ƙwayoyin halitta: ƙungiyar halittu Ⅰ (Up) da ƙungiyar halittu Ⅱ (Uu). Biogroup I ya haɗa da nau'ikan serotypes 4 tare da ƙananan kwayoyin halitta (1, 3, 6, da 14); biogroup II ya haɗa da sauran nau'ikan serotypes 10 tare da manyan kwayoyin halitta.

Tashar

FAM UU nucleic acid
VIC (HEX) Sarrafa Cikin Gida

Sigogi na Fasaha

Ajiya Ruwa mai ruwa:≤-18℃ Cikin duhu
Tsawon lokacin shiryawa Watanni 12
Nau'in Samfuri fitsarin namiji, swab na fitsarin namiji, swab na mahaifar mace
Ct ≤38
CV ≤5.0%
LoD Kwafi 50/ra'ayi
Takamaiman Bayani Babu wani haɗin gwiwa tsakanin wasu ƙwayoyin cuta masu kamuwa da cutar STD a waje da kewayon gano kayan aikin, kamar Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, herpes simplex virus type 1, da kuma herpes simplex virus type.
Kayan Aiki Masu Amfani Zai iya daidaita manyan kayan aikin PCR masu haske a kasuwa.Tsarin PCR na Zamani na Aiyuka 7500Tsarin PCR na Ainihin Lokaci 5 na QuantStudio®

Tsarin PCR na SLAN-96P na Lokaci na Gaskiya

Tsarin PCR na LightCycler®480 na Ainihin Lokaci

Tsarin Gano PCR na Layin Ganowa na Layin Ganowa na 9600 Plus na Lokaci-lokaci

Mai Keke Mai Zafi na MA-6000 na Ainihin Lokaci

Tsarin PCR na BioRad CFX96 na Ainihin Lokaci

Tsarin PCR na BioRad CFX Opus 96 na Ainihin Lokaci

Tsarin aiki

Kit ɗin Gano Acid na Ureaplasma (PCR mai haske)

Ana buƙatar reagent amma ba a bayar da su ba

Maganin Sample Release Reagent na Macro & Micro-Test (HWTS-3005-8), Kit ɗin DNA/RNA na Macro & Micro-Test Viral (HWTS-3017) (wanda za a iya amfani da shi tare da Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) ta Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Maganin Noma na Saline, maganin kiyaye fitsari.

Ana buƙatar kayan amfani amma ba a bayar da su ba

1.5mL na bututun centrifuge mara DNase/RNase, Tips mara DNase/RNase, ethanol mai hana ruwa, pipette, centrifuge na tebur, mahaɗin benci


  • Na baya:
  • Na gaba:

  • Rubuta saƙonka a nan ka aika mana da shi