Kit ɗin Gano Acid na Neisseria Gonorrhoeae (Ƙara Ƙarfafa Ƙarfin Enzymatic Probe)
Sunan Samfuri
Kit ɗin Gano Acid na Neisseria Gonorrhoeae (Ƙara Ƙarfafa Ƙarfin Enzymatic Probe)
Takardar Shaidar
CE
Ilimin Cututtuka
Cutar gonorrhea cuta ce da ake kamuwa da ita ta hanyar jima'i wadda ke faruwa sakamakon kamuwa da cutar gonorrhoeae ta Neisseria (NG), wadda galibi take bayyana a matsayin kumburin da ke cikin membranes na mucous na tsarin genitourinary. A shekarar 2012, Hukumar Lafiya ta Duniya (WHO) ta kiyasta cewa akwai mutane miliyan 78 da suka kamu da cutar a duk duniya. Gonorrhoeae ta Neisseria ta mamaye tsarin genitourinary da kuma haifar da urethritis a cikin maza da kuma urethritis da cervicitis a cikin mata. Idan ba a yi maganinta gaba daya ba, tana iya yaduwa zuwa tsarin haihuwa. Za a iya kamuwa da tayin ta hanyar hanyar haihuwa wanda ke haifar da gonorrhea acute conjunctivitis a jarirai. Mutane ba su da kariya ta halitta ga gonorrhoeae ta Neisseria, kuma duk suna da saukin kamuwa. Garkuwar bayan rashin lafiya ba ta da ƙarfi kuma ba za ta iya hana sake kamuwa da cutar ba.
Tashar
| FAM | NG nucleic acid |
| CY5 | Sarrafa Cikin Gida |
Sigogi na Fasaha
| Ajiya | Ruwa: ≤-18℃ Cikin duhu; An yi shi da Lyophilized: ≤30℃ Cikin duhu |
| Tsawon lokacin shiryawa | Ruwa: Watanni 9; An yi shi da Lyophilized: Watanni 12 |
| Nau'in Samfuri | Fitsari ga maza, swab na fitsari ga maza, swab na mahaifa ga mata |
| Tt | ≤28 |
| CV | ≤5.0% |
| LoD | Guda 50/mL |
| Takamaiman Bayani | Babu haɗin gwiwa da wasu ƙwayoyin cuta masu kamuwa da cututtukan ciki kamar su HPV type 16 mai haɗari, human papillomavirus type 18, herpes simplex virus type 2, treponema pallidum, M.hominis, Mycoplasma genitalium, Staphylococcus epidermidis, Escherichia coli, Gardnerella vaginalis, Candida albicans, Trichomonas vaginalis, L.crispatus, adenovirus, cytomegalovirus, Group B Streptococcus, HIV virus, L.casei, da kuma DNA na halittar ɗan adam. |
| Kayan Aiki Masu Amfani | Tsarin PCR na Zamani na Aiyuka 7500 Tsarin PCR na SLAN-96P na Lokaci na Gaskiya Tsarin PCR na LightCycler®480 na Ainihin Lokaci Tsarin Gano Zazzabi Mai Sauƙi na Haske na Amp HWTS1600 na Ainihin Lokaci |
Ana buƙatar reagent amma ba a bayar da su ba
Maganin Sample Release Reagent na Macro & Micro-Test (HWTS-3005-8), Kayan Aikin DNA/RNA na Macro & Micro-Test Viral (HWTS-3001, HWTS-3004-32, HWTS-3004-48) da kuma Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006), gishirin yau da kullun.
Ana buƙatar kayan amfani amma ba a bayar da su ba
1.5mL na bututun centrifuge mara RNase/DNase, Tips mara RNase/DNase, centrifuge na tebur, mahaɗin girgiza tebur, wurin maganadisu, wanka na ƙarfe mai zafi.